Skip to main content

IAR Embedded Workbench for Arm 9.70.x

__setDataBreak

In this section:
Syntax

In the simulator:

__setDataBreak(location, count, condition, cond_type, access, action)

In the C-SPY I-jet driver and in the C-SPY CMSIS-DAP driver:

__setDataBreak(location, access, extend, match, data, mask)
Parameters
location

A string that defines the data location of the breakpoint, either a valid C-SPY expression whose value evaluates to a valid address or an absolute location. For information about the location types, see Enter Location dialog box.

count

An integer that specifies the number of times that a breakpoint condition must be fulfilled before a break occurs the next time.

This parameter only applies to the simulator.

condition

The breakpoint condition (string).

This parameter only applies to the simulator.

cond_type

The condition type; either "CHANGED" or "TRUE" (string).

This parameter only applies to the simulator.

access

The memory access type: "R", for read, "W" for write, or "RW" for read/write.

action

An expression, typically a call to a macro, which is evaluated when the breakpoint is detected.

This parameter only applies to the simulator.

extend

Extends the breakpoint so that a whole data structure is covered. For data structures that do not fit the size of the possible breakpoint ranges supplied by the hardware breakpoint unit, for example three bytes, the breakpoint range will not cover the whole data structure. Note that the breakpoint range will be extended beyond the size of the data structure, which might cause false triggers at adjacent data. Choose between "TRUE"or "FALSE".

This parameter only applies to the C-SPY I-jet driver and the C-SPY CMSIS-DAP driver.

match

Enables matching of the accessed data. Choose between "TRUE"or "FALSE".

This parameter only applies to the C-SPY I-jet driver and the C-SPY CMSIS-DAP driver.

data

A data value to match, in unsigned 32-bit format.

This parameter only applies to the C-SPY I-jet driver and the C-SPY CMSIS-DAP driver.

mask

Specifies which part of the data value to match—word, halfword, or byte—in unsigned 32-bit format.

This parameter only applies to the C-SPY I-jet driver and the C-SPY CMSIS-DAP driver

Return value

Result

Value

Successful

An unsigned integer uniquely identifying the breakpoint. This value must be used to clear the breakpoint.

Unsuccessful

0

Table 54. __setDataBreak return values 


For use with

The C-SPY simulator.

The C-SPY CMSIS-DAP driver.

The C-SPY GDB Server driver.

The C-SPY G+LINK driver.

The C-SPY I-jet driver.

The C-SPY J-Link driver.

The C-SPY PE micro driver.

The C-SPY ST-Link driver.

The C-SPY TI MSP-FET driver.

The C-SPY TI Stellaris driver.

The C-SPY TI XDS driver.

Description

Sets a data breakpoint, that is, a breakpoint which is triggered directly after the processor has read or written data at the specified location.

Example

For the C-SPY simulator:

__var brk;
brk = __setDataBreak(":0x4710", 3, "d>6", "TRUE",
      "W", "ActionData()");
...
__clearBreak(brk);

For I-jet:

__var brk;
brk = __setDataBreak("myVar", "W", "FALSE", "TRUE", 
     0xABCD, 0xFFFF);
...
__clearBreak(brk);