__setSystemTimeout
In this section:
Syntax
__setSystemTimeout(timeout)Parameters
timeoutThe timeout in milliseconds.
Return value
The most recent value set by this macro, or 10000 (the default value) if the macro has not been called before.
For use with
All C-SPY drivers.
Description
Use this macro to set the timeout for an external application started with one of the macros __system1, __system2, or __system3. By default, the timeout is set to 10,000 milliseconds (10 seconds).
Example
__var exitCode;
__var out;
__var oldSize;
__var oldTimeout;
oldSize = __setSystemMaxData(100000);
oldTimeout = __setSystemTimeout(60000); // Changing the timeout to one minute
exitCode = __system2("dir /S", &out);
__message "Previous data limit:";
__message oldSize
__message "Previous timeout:";
__message oldTimeout;
__message "Output from the dir command:";
__message out;See also
__setSystemMaxData, __system1, __system2, and __system3.
Note